Key features & benefits
Direct/Indirect lighting: Uniform light distribution across the treatment room.
High Colour rendering for accurate shade matching (CRI >97).
Flicker free: no fatigue inducing flicker.
Low glare: Light is not harsh & unpleasant on they eyes.
High output: 1500–2000 lux at the oral cavity.
Installation
DentLed partners with certified installers for lighting installation. Contact us for possibilities.
Technical specifications
PVR150 | |
Output (lumen) | 28.000 lm |
CRI (Colour Rendering) | 97+ |
CCT (Colour Temp) | 5000 K |
Efficacy | 129 lm/W |
Power Consumption | 210 W |
Outer diam | 150 mm |
Profile (w x h) | 50 x 60 mm |
Weight | 12 kg |
Color | custom |
Flicker Free | Yes |
Lifetime | 50,000 hrs |
Power Cord Length | 3 m |
UGR | <17.8 |
Direct/Indirect | 66% / 33% |
Dimmable | Option/dali incl |
Ext driver housing | diam 260 mm / height 50 mm |
Ext driver housing colour | white or black |
Suspension | Fixed: 4 cables |
Experience Light OPTIMALLY
The fixtures feature both 50% of direct as well as 50% of indirect light, which makes for a generous light distribution in your treatment room. The direct and indirect light is shielded by a high-quality prismatic diffuser. This ensures that the light is evenly distributed and yet comfortable for the eyes and the patient will not be blinded by the Dentled lighting despite the high light intensity. Dentled LED lighting is generally experienced as soft light.
Various CONFIGURATIONS
Every room has different requirements based on its use, size, position of the surgical lamp and colour scheme of the walls and ceiling. These factors have a direct influence on the composition and/or choice of the dental luminaire model.
Next to the direct/indirect version, the PVR150 ( 1500mm) ring fixture is also available in a direct variant, meant for rooms with a low ceiling where the effect of indirect lighting is negligible.The higher a suspended fixture is hung, the less indirect light is emitted. In many cases, a PVR fixture is suspended at a height of 2.2 metres from the floor.
More information about PVR
- energy efficient and optimal light distribution thanks to direct and indirect lighting (50.000+ hours L90B10)
- diameter 1500x50x60mm profile 5000k cri90+ 80w 28000lm DALI and 1200x50x60mm
- a high RA value of 93.5 allowing for an unblemished color determination and UGR <19 avoids unpleasant glares
- no negative influence on curing of composite and or glue thanks to the full spectrum daylight at 2000 lux
- meets the specified minimum of 1500- 2000 lux illuminance at your workplace (headrest of the treatment chair in treatment position)
- the use of flicker-free drivers, less strenuous for the eyes by avoiding the 50hz flickering of the light source